COMPONENT TESTING INFORMATION
Illustration Components Test Procedures Results
Broil Burner Verify gas is supplied
Proper orifice installed for
Natural or LP.
Check for damage to screen. Replace if punctured or torn
Pressure regulator Verify gas pressure (WPC) 5” Natural gas
If on LP service verify gas 10” LP/Propane
supply conversion.
Norton Ignitor Test for voltage at terminals. 120 VAC
Teat for the amount of amperage 3.2 – 3.6 Amps.
in the circuit (Ignitor may glow
but not have sufficient amperage
to open valve)
Gas valve Disconnect wiring to valve
Measure resistance on bake
circuit. Continuity
Measure resistance on broil
circuit. Continuity
Shut off valve Check to verify gas supply is
Turned on.