COMPONENT TESTING INFORMATION
Illustration Components Test Procedures Results
Oven light socket Test continuity receptacle Indicates continuity with bulb
terminals. screwed in.
Measure voltage at oven light 120VAC, see wiring diagram for
terminal identification. If no
voltage is present at oven light
check wiring.
Hinge Carefully open the hinge fully, &
Insert a wooden dowel or screw-
Driver bit into opening. Remove
top and bottom screws securing Do not place hands in hinge area
hinge. Slide hinge top toward when oven door is removed.
rear of unit and guide hinge out Hinge can snap closed and pinch
through frame opening or storage hands or fingers.
drawer.
Blower motor Verify supply voltage. 120 VAC
Disconnect and check continuity Continuity.
to motor at the terminals, and
verify terminals are not shorted
to chassis.
Heraeus sensor Measure resistance. Approximately 1100 at room
temperature.
Door lock switch Switch connections in following Normally open.
Positions:
Unlocked
Com-NO=Open, Com-NC=Closed
Locked
Com-NO=Closed, Com-NC=Open
Sail switch Switch connections in following Normally open.
position:
Not ingaged
Com-NO=Open, Com-NC=Closed
Engaged
Com-NO=Closed, Com-NC=Open
Controls Verify proper operation. Normally open
31833001 Control limit Opens at 145°F, Closes at 185°F
042056 Fan switch 1-2 (NO) Opens at 120°F, Closes at 150°F
1-3 (NC) Opens at 150°F, Closes at 120°F
Bake Burner Verify gas is supplied.
Orifice adjusted for Natural or
LP. Check for obstructions or
Contamination in ports