TROUBLE SHOOTING
GUIDE__---- FREESTANDING GAS RANGE ----
PROBLEM PROBABLE CAUSE CORRECTION
18.Flashback-The air/gas mixture 18A. Under rated burner 18A. Check orifice size. Increase size if
ignites inside the burner to
necessary or increase gas
pressure.
burn near the orifice, creating 18B. Increase primary air. 18B.
Adjust air shutter to reduce
primary
a roaring noise like a blow air.
torch. 18C.
Flashback occurs with the
18C. Change burner valve.
Burner valve in on off
18D. If #1,2 &3 corrections fail to
probably , the valve is eliminate flash back, replace the
probably leaking. burner.
19. Extinction pop-A small 19A. Similar to flashback. 19A. Reduce primary air supplied to
explosion of gas in the the burner. CAUTION: do not
burner head occurs when
allow yellow tipping during
normal
the burner is shut off. burner operation.
19B. Check orifice size.
19C. Check gas pressure.
Check the gas supply and set the regulator to the proper supply of gas. A properly adjusted burner should
be stable and quiet. The flame should have a sharp, well defined blue inner cone, no yellow tipping. The
flame should also be stable and uniform with no flames lifting off the burner ports.
A. VGRC / VGSC I / R broiler construction
prior to Feb. 1995 used one (1) screen
support. The support was mounted
internally from the venturi forward to the
front of the broiler burner box. The screen
support partially covered the glow coil
ignitor. This usually caused slow or delayed
ignition, especially when used LP gas.
B. A change in the manufacturing of the I / R
broiler repositioned the screen supports.
The screen supports, now two (2), are
positioned from, right to left. The glow coil
ignitor is now completely open for igniting
the gas almost immediately.
C. The first generation, VGR / VCM, screen
support should be welded in four (4)
places. A limited production run used
pop rivets. The center of the rivets may
fall out causing the broiler to back flash
to the venturi. Should this occur you can
close the opening with a #6 machine
screw. Any rear or puncture in the screen
or opening in any welded seam will
also cause the broiler to back flash.