PROBLEM POSSIBLE CAUSE TEST PROCEDURE-
Freezer compartment too High ambient temperature Locate in area our of direct rays of
warm (continued) sun and away from heat registers or
other source of heat.
Cabinet light Check to make sure door switch is
closed. Replace or adjust switch if
necessary.
Excessive frost on evapo-
Check items under complaint,
“incom-
rator. plete defrosting.”
Unit:
a. Compressor won’t Check items under complaint,“Com-
Run pressor won’t run.
b. Compressor runs Check items under complaint,“Com-
continuously pressor runs, but no refrigeration or
insufficient refrigeration.
Refrigerator compart- Motorized Air Door:
Check for a motor winding
resistance of
ment too warm 8800 ohms between the BE/Y andW
a. Baffle closed wires or the Y/R and W wires. If the
meter reading shows “open”for both
BE/Y and Y/R wires, replace motor.
b. Baffle is stuck closed Check for iced door.Remove ice and
eliminate moisture entering due to
air leak.
Electronic control board:
a. Set too warm Turn knob to colder position.
b. Baffle stuck closed Check for 120 v. between the
OR/W
and W wires at circuit board plug.
NOTE: Use static control gloves
when handling electronic control
board.
Thermistor:
a. Sends wrong or high
Check resistance for given
temperature
resistance signal to at
GY
wires.An open or infinite resis-
control board. tance reading closes the door.Replace
the thermistor.
b. Others, same as Same as items under, “Freezer
“Freezer compart- compartment too warm.”
ment too warm