PROBLEM PROBABLE CAUSE CORRECTION
6. No broil: 6A. Open contacts in the Selector 6A. Check continuity from 1 to 11
Selector Switch set to Broil Switch. on the Selector Switch. If
Temperature set to Broil open replace Selector Switch.
Bake functions normally Check wiring.
Cycle Light is on 6B. Direct Spark Ignition Module 6B. Check for 120VAC at pin 7
Broil Ignitor does not click (DSI) inoperative. (BR / RED) on the Module.
Gas supply tubing on wrong If voltage is present, replace
Gas Valve Module. No voltage check
wiring.
7. No Broil: 7A. Open coil in Broil Solenoid 7A. Check continuity across Broil
Selector Switch set to Broil valve. Valve. If open, replace valve.
Temperature set to Broil 7B. Air in the gas line. 7B. Purge the gas line, turn the
Bake functions normally control off and retry.
Cycle Light is on
Broil Ignitor clicks
8. No Convection Broil: 8A. Open contacts in the Selector 8A.Check continuity from 5 to 7 on
Selector Switch set to Broil Switch. The Selector Switch. If open
Temperature set to Broil replace Selector Switch
Broil Functions normally 8B. Open Windings in the 8B. Check continuity across the
Convection Fan Motor.
Motor windings. If open replace
Motor. Check wiring.
9. No Self-clean: 9A. Selector Switch contacts 9A. Check continuity from contact
Before Door Lock 2 to 10 open
2 to 10. If open replace
Selector
Selector Switch to Clean Switch. Contacts okay, check
Thermostat to Clean for Power at T2 on the Timer
(Against the upper stop) PCB. No power , check the
Bake functions normally wiring from Selector Switch
Broil functions normally form the Selector Switch to the
Clean Light does not light Timer (PC) Board.
Door does not lock 9B. Selector Switch contacts 9B. Check continuity from contact
5 to 6 open 5 to 6. If open replace the
Selector Switch. Contacts
okay, check for power at SEL on
the timer PC board. No power
check the wiring from selector
Switch to Timer PCB.
9C. No power to L1 on the 9C.
Check wiring from L2 to
L1.On
Timer PCB. Timer PCB.
9D. No power to Pin 1 on the 9D. Check continuity from Timer
Auto Reset PCB Pin L1 to LS1. If open
replace the Timer PCB.
9E. No Power to Timer PCB 9E. Auto Reset not closing. Check
` contact LS2. Continuity from Auto Reset
Pin 1 to Pin 2. If open replace
Auto Reset. Contact okay
check wiring from Auto Reset
Pin 2 to Timer PCB Pin LS2.
89