Component Description Test Procedures
Switch, showroom ON position completes circuit to Check resistance at test points.
lights and display only. Showroom operation—E3 at high voltage board to pin
3 (blue/white wire) at high voltage wire harness.
OFF position completes circuit
for normal operation. Unit run—E9 at high voltage board to pin 3 (blue/white
wire) at high voltage wire harness.
Unit shipped with switch in OFF
position.
Thermistor Senses temperature within Check resistance across terminals. See Technical Data
Refrigerator and freezer.
Sheet for bell curve resistance chart at given
temperatures.
Thermostat Thermostat is in a serried circuit With power off and evaporator coil below freezing,
with high voltage board and thermostat should check continuous when checked with
defrost heater. ohmmeter . See “Heater, evaporator (defrost)” section
for additional tests.
Controls the circuit through
defrost terminator to defrost
heater. Opens and breaks
circuit when thermostat senses
high temperatures.
After defrost thermostat opens,
thermostat remains open until
end of defrost cycle and refrig-
erator starts cooling again.
when defrost thermostat senses
a preset low temperature and
closes.
Valve, water Controls water flow to the ice Check resistance across coil windings. See Technical
maker. Data Sheet for valves for model being serviced.