Viking VUAR140 Troubleshooting Guide Page 41

  • Download
  • Add to my manuals
  • Print
  • Page
    / 92
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 40
TESTING PROCEDURES
Relay Board 2
The relays for oven light, bake, broil, convection
element, convection fan and double line break
are controlled by approximately 24 volts from
ERC. Input voltage is 102-132 VAC.
Testing of the relays is with voltage applied to
oven after attaching voltmeter leads to
appropriate terminals.
NOTE: If bake, broil, or convection do not
work, the first test would be the relay for double
line break.
Bake Relay –K2
Double line break relay okay. Drive voltage at
J1 connector pins 4 and 5.
1. Turn off power to oven.
2. Attach voltmeter lead to gray wire
connection on double line break relay.
3. Attach voltmeter lead to E3 (BA) connector
on relay module.
4. Turn on power and touch the bake pad.
5. If 24 VAC is indicated bake relay is
operating.
Broil Relay --K3
Double line break relay okay. Drive voltage at
J1 connector pins 3 and 5.
1. Turn off power to oven.
2. Attach voltmeter lead to gray connection on
double line break relay.
3. Attach voltmeter lead to E6 (BR) connector
on relay module.
4. Turn on power and touch broil pad.
5. If 24 VAC is indicated broil relay is
operating.
Double Lock Relay –K4
Double line break relay okay. Drive voltage at
J1 connection pins 1 and 7.
1. Turn off power to oven.
2. Attach voltmeter lead to E3 (neutral)
connection on transformer/relay board 1.
3. Attach voltmeter lead to E2 connector on
relay module.
4. Turn on power and program cleaning cycle
operation.
5. Two indications will be present during this
test.
120 VAC will be present during the
lock assembly is being engaged.
0 VAC is indicated when the door
is locked and cleaning cycle is
operational.
42
Page view 40
1 2 ... 36 37 38 39 40 41 42 43 44 45 46 ... 91 92