Illustration Component Test Procedure Results
See Illustrations Mylar touch F1 - Control malfunction. Test mylar touch pad.
above system F2 - Oven over temperature. Check sensor wiring, sensor, and
temperature limiter.
F3 - Open sensor or sensor circuit Check sensor resistance and wiring.
F4 - Shorted sensor or sensor circuit Check sensor resistance and wiring.
F7 - Shorted input key. Verify mylar switch connections, replace
mylar touch switch.
F9 - Door lock or door lock circuitry Check latch switch.
malfunction (door unlocked)
FF - Door lock or door lock circuitry Check latch switch
malfunction (door locked)
Door - Lock status is not sensed within Verify operation of door latch switches.
90 seconds of energizing door lock relay.
ERC control Oven Press Bake While increasing or decreasing oven
temperature Press + slew pad until an oven temperature, this does not affect self-
adjustment temperature greater than 500° shows cleaning temperature.
on display.
Immediately press and hold BAKE until
“00" appears in display, approximately
5 seconds.
To decrease oven temperature (for a
cooler oven), press - slew pad until
negative numbers appear. Oven can be
adjusted from -5° to -35° lower.
To avoid over adjusting oven move
temperature -5° each time.
` To increase oven temperature (for
warmer oven), press + slew pad until
positive numbers appear. Oven can be
adjusted 5° to 35° higher. To
avoid overadjusting oven move
temperature 5° each time.
Press OFF / CANCEL. Temperature
adjustment will be retained even though
power failure.
ERC control Twelve hour Control will automatically cancel any
off baking operation and remove all relay
drives 12 hours after the last pad touch.
ERC control Child lock out This is a safety feature that can be used
to prevent children from accidentally
programming the oven. If disables the
electronic oven control. Press and hold
BAKE and BAKE TIME for approximately
5 seconds. “Off” will display where the
temperature normally appears.
To reactivate the control, press and hold
BAKE and BAKE TIME for 5 seconds.
Child lockout features must be reset after
a power failure.