COMPONENT TEST PROCEDURE METER READING
TIMER
(Continued) 1b. Mallory Timer: Touch the Mallory Timer - the meter should
meter probes to timer ter- read 6000 ohms to 9000 ohms.
minals PK and R (motor
windings).
The Defrost Mode
1. Set the ohmmeter to Rx1
scale and zero the meter.
2. Touch the meter probes The meter should read “ zero” resistance
to timer terminals PK and (contacts closed.) If it reads anything
BK (switch contacts.) else, replace the timer.
3. Touch the meter probes The meter should read “infinity” (con-
terminals BK and OR tacts open.) If it reads anything else,
(switch contacts.) replace the timer.
Cooling Mode
1. Use a screwdriver and
Manually advance the
Time 1/4 turn.
2. Touch the meter probes The meter should read “zero” resistance
to timer terminals BK (contacts closed.) If it reads anything
and OR (switch contacts.) else, replace the timer.
3. Touch the meter probe The meter should read “infinity” (con-
to timer terminals PK tacts open.) If it reads anything else
and BK (switch contacts.) replace the timer.