Ice Maker Troubleshooting Chart ---VCBB Bottom Freezer - Refrigerator---
Excessive Ice Production
Problem Action
Shut-off arm not in actuator Replace shut-off arm in actuator
Deformed Shut-off arm Replace shut-off arm
Broken shut-off lever or Replace module
lever bypassing vertical cam
Broken module actuator Replace module
Hollow Ice Cubes
Low water fill volume Adjust module screw, clear water path,
or replace water valve
Improper freezer air-flow Direct air flow away from thermostat
Thermostat out of calibration Replace thermostat
Apply alumilasic
Flooding or Ice in Bucket or Freezer
Thermostat out of calibration Replace thermostat
Apply alumilastic
Jammed cube stalled in water-fill cycle Remove cube
Determine reason for stall
Leaky water valve Replace water valve
Excessive water fill volume Replace water valve
Motor stalled in water-fill cycle Replace module
(12: ejector position)
Contaminated module Replace module
Refrigerator or ice maker not level Level refrigerator or ice maker
Excessive water pressure Decrease water pressure (20-120 psi) (1.4- 8.2bar)
Shorted and burned module shut-off Replace module
switch and contacts
Broken locking tab on verticle cam Replace module
(Stalled in water fill)
Fill-tube not properly positioned in Reposition fill tube
fill cup
Fill cup water opening blocked Replace fill cup
Cubes fall over back of ice maker, Replace fill cup
melting in freezer