Wiring: Schematic ---VCBB Bottom Freezer -Refrigerator---
Adaptive Defrost Theory of Operation: After designated compressor run time, refrigeration cycle is interrupted
and electronic control sends a low voltage signal to defrost relay coil (def D1). Powering the relay coil closes
contact (D1) completing high voltage circuit to defrost heater through closed defrost terminator (closes at 15°F).
Isolator, which is part of high voltage PC board, recognizes presence of line voltage to defrost heater and sends low
voltage signal to electronic control. Electronic control keeps count of number of minutes, defrost terminator
remains closed (opens at 48°F). length of time defrost terminator is closed determines if the next defrost cycle
advances by 4 hours of compressor run time, stays at the same interval, or delays by 4 hours of compressor run. If
defrost terminator does not open before 29 minutes, defrost cycle is automatically terminated by electronic control
and refrigeration cycle will resume after 6 minutes dwell time.