VOLTAGE READINGS
POINT NORM DRAIN HEAT WASH DRY
*DRAIN 120 120 120 120 120
PUMP
*BLOWER 120 120 120 120 120
SOAP 0 0 3 0 3
SOL.
TIMER
POINTS
P1 0 120 3 120 3
P1B 0 120 3 9 3
P2a 0 120 3 0 3
(INLET
VALVE)
P3 0 120 3 120 3
P4 120 120 120 120 120
P4a 0 120 120 120 120
P5b 6 6 10 15 7
*Drain Pump and Blower Fan will always have voltage present. The Timer completes the
circuit to allow the Motors to run. This is normal and should not be considered a Timer fault.
RESISTANCE READINGS
All resistance readings should be taken with the component disconnected and no voltage
present so as not to damage meter.