Data Cables
Data cables are 4-pair CAT 5e or equivalent
x Must be plenum-rated
x Straight-pin cable (Pin 1->1, Pin 2->2, Pin 3->3,
Pin 4->4, Pin 5->5, Pin 6->6, Pin 7->7, Pin 8->8)
Data connectors: RJ45
NOTE: Do NOT run data cable along side power wires.
Data wires must run at right angles to power wires
found in the plenum. Follow all proper procedures &
local codes.
TIA/EIA 568-B Configuration
1. Run data cable from the i.Lon
®
network hub or MPI in the electrical/IT closet to
the first OP and continue with the data wire from each OP in sequence.