A. Definitions
Master Module: The C-3000 module assigned module ID #1. Also, the only module in a single-module system.
Slave Module(s): Any module(s) in addition to the Master, in a multi-module C-3000 system. Slave modules are
assigned module ID numbers in the range of #2 through #8.
“66” Punch Down Terminal Block: A connection peripheral used to interface telephone lines easily. This installation
requires a “split” punch down block.
B. Preparing the Installation
Select an appropriate location in which to install the C-3000 System. It is normally most convenient to install the C-3000
modules as near as possible to the telco demarcation point; that is, the common point at which all tenant phone lines
enter the building (if applicable). If the tenant phone wiring is not currently cabled though a "66" block or blocks, it will
be necessary to install "66" block(s) at this time to facilitate the installation of the C-3000 system. Note: See the instal-
lation diagram on the following page for recommendations on which “66” block to use.
C. Assigning Module ID Numbers
A C-3000 system consists of at least one (Master) C-3000 module, and as many as seven (7) Slave modules. Multiple
C-3000 modules are all interconnected from module to module, using the supplied modular cords, connecting the
MULTI-MODULE INTERCONNECTS from IN to OUT. If more than one C-3000 module is being installed, it will be nec-
essary to set module ID numbers at this time. Each C-3000 module must have it's own ID number to be part of a C-
3000 system. Module ID numbers are set using the three-position DIP switches on the front of the C-3000 modules
(see diagram below). Module ID numbers are used to determine which C-3000 module is responsible for handling a
particular range of apartment numbers. As an example, Module #1 (the Master module) handles apartment numbers 1-
12, Module #2 handles apartment numbers 13-24 and so forth.
D. Wiring Table
Refer to the wiring table below when installing the cabling for the C-3000 system. Note that tenant line 1 enters on pins
1 & 26 of the RJ-21X connector, and exits on pins 2 & 27 of the same connector. This also means a visitor would dial
a touch tone 1 to call the tenant connected to line 1. This scheme is used on all 12 lines on the RJ-21X connector,
occupying all pins up thorough the pin 24 & 49 pair, and repeats on up to the 96th tenant on the
8th module. The last pair on the RJ-21X connector (pins 25 & 50) has a special function. This
last pair is used (on the Master module only) as a connection for the Building Manager's
Programming Phone.
Module ID
Assignment
Module 2
“Slave”
13
14
15
16
17
18
19
20
21
22
23
24
13
14
15
16
17
18
19
20
21
22
23
24
n/a
Module 3
“Slave”
25
26
27
28
29
30
31
32
33
34
35
36
25
26
27
28
29
30
31
32
33
34
35
36
n/a
Module 4
“Slave”
37
38
39
40
41
42
43
44
45
46
47
48
37
38
39
40
41
42
43
44
45
46
47
48
n/a
Module 5
“Slave”
49
50
51
52
53
54
55
56
57
58
59
60
49
50
51
52
53
54
55
56
57
58
59
60
n/a
Module 6
“Slave”
61
62
63
64
65
66
67
68
69
70
71
72
61
62
63
64
65
66
67
68
69
70
71
72
n/a
Module 7
“Slave”
73
74
75
76
77
78
79
80
81
82
83
84
73
74
75
76
77
78
79
80
81
82
83
84
n/a
Module 8
“Slave”
85
86
87
88
89
90
91
92
93
94
95
96
85
86
87
88
89
90
91
92
93
94
95
96
n/a
ON
OFF
123
ON
OFF
123
ON
OFF
123
ON
OFF
123
ON
OFF
123
ON
OFF
123
ON
OFF
123
ON
OFF
123
DIP Switch
Settings
C.O.
Lines In
Lines Out
to
Apartment
Phones
(Dial Up
Codes)
Tip
26 W/BL
28 W/G
30 W/S
32 R/O
34 R/BN
36 BK/BL
38 BK/G
40 BK/S
42 Y/O
44 Y/BN
46 V/BL
48 V/G
27 W/O
29 W/BN
31 R/BL
33 R/G
35 R/S
37 BK/O
39 BK/BN
41 Y/BL
43 Y/G
45 Y/S
47 V/O
49 V/BN
50 V/S
Ring
1 BL/W
3 G/W
5 S/W
7 O/R
9 BN/R
11 BL/BK
13 G/BK
15 S/BK
17 O/Y
19 BN/Y
21 BL/V
23 G/V
2 O/W
4 BN/W
6 BL/R
8 G/R
10 S/R
12 O/BK
14 BN/BK
16 BL/Y
18 G/Y
20 S/Y
22 O/V
24 BN/V
25 S/V
Bldg Mgr Phn
VIKING
©
MODEL C-3000
VIKING
ELECTRONICS
HUDSON, WI 54016
12 UNIT APARTMENT
ENTRY CONTROLLER MODULE
POWER
13.8 VAC
3456712
DOOR
STRIKE
1
DOOR
STRIKE
2
DIP
SWITCH
1 2 3
RJ21X
12 APARTMENT LINES IN/OUT
8
ENTRY
PHONE 1
MULTI-MODULE
INTERCONNECTS
POSTAL
LOCK
INPUT
ENTRY
PHONE 2
OUT IN
PWR
IN
USE
PROGRAM PHONE
O
N
O
F
F
RJ-21X
2
Page view 1
1 2 3 4 5 6 7 8

Comments to this Manuals

No comments