Viking Alarm Dialers Manual

Browse online or download Manual for Security access control systems Viking Alarm Dialers. Viking Alarm Dialers Product manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
PRODUCT MANUAL
Designed, Manufactured and Supported in the USA
COMMUNICATION & SECURITY SOLUTIONS
Voice Alarm Dialing from Two Inputs
Features
Viking’s K-202-DVA is a fully programmable two-
input, multi-number auto dialer, designed for emer-
gency and non-emergency message notification.
The K-202-DVA has two dry contact inputs, each
of which can dial up to seven 32-digit phone num-
bers and play a message up to 1 minute in length
specific to that input.
Messages can be recorded locally or remotely with
a total message time for both inputs of two min-
utes. The K-202-DVA has call progress detection
capability with normal and fast busy, call pickup,
CPC and ring-no-answer detection. Programming
is easily done with a Touch Tone phone.
• Non-volatile memory (no batteries required)
• Stores up to seven 32-digit phone numbers per input
(fourteen 32-digit numbers total)
• 2 minutes of record time (1 minute per input)
• Programmable message repeat counter
• Programmable lap counter
• Two inputs programmable for normally open or nor-
mally closed and enabled or disabled
• Programmable ring delay for remote programming and
alarm polling
• Programmable qualifier timer for each input (time for
an event to be qualified as an alarm)
• Programmable resume timer for each input (time fol-
lowing reset for input to become active again)
• Call progress detection
• Programmable ringback limit for call progress
• Remote security and access codes
• Local or remote programming and recording
• Compatible with the RC-2A and RC-3 remote DTMF
controllers
• Phone numbers may be programmed as pager num-
bers (no voice message played)
• Programmable hookswitch flash before dialing
• Local reset input
• Local alarm state indication LED
• Security/burglar/fire alarm notification
• System alarm or equipment malfunction notification
• Environmental warning notification
• Contacting personnel via numeric pagers
Power: 120V AC/12V DC 500 mA, UL listed adapter pro-
vided
Dimensions: 133mm x 91mm x 44mm (5.25” x 3.6” x
1.75”)
Shipping Weight: 0.68 Kg (1.5 lbs)
Environmental: 0°C to 32°C (32°F to 90°F) with 5% to
95% non-condensing humidity
Talk Battery: 12V DC
Touch Tone Dialing: 100 ms on/off, 50 ms on/off
CPC Detection Time: 320 ms minimum
Message Record Time: 2 minutes
Sampling Rate: 64 K (equivalent)
Input Detection Time: 90 ms with Qualifier Timer set to
0
Resolution Qualifier Timer: 1 second to 18 hours (see
page 3)
Resolution Resume Timer: 1 second to 18 hours (see
page 3)
Connections: (1) RJ11 jack for telco connection, (1) 6 po-
sition screw terminal block for inputs
K-202-DVA
Two-Input Voice
Alarm Dialer
February 20, 2014
Applications
Specifications
www.vikingelectronics.com
Information: (715) 386-8861
VIKING
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - PRODUCT MANUAL

PRODUCT MANUALDesigned, Manufactured and Supported in the USACOMMUNICATION & SECURITY SOLUTIONSVoice Alarm Dialing from Two InputsFeaturesViking’s

Page 2 - Definitions

Definitions2Alarm Dialer: The K-202-DVA calls the list of up to 7 phone numbers associated with an alarm input when the inputhas reached the alarm sta

Page 3 - Programming

Note: Correct programming entries are implemented and then acknowledged by two beeps. Incorrectprogramming entries are discarded and receive three bee

Page 4 - C. Factory Default Settings

To program one of the seven phone numbers for each alarm input as a pager number enter: the desired 1-32 digit pagerphone number + #Q + XY (where X is

Page 5

Enter one digit from 0-9 followed by #92. If the ring delay is set to 0, ring detection is disabled, so that the K-202-DVA will not answer incoming c

Page 6 - Operation

The PA mode allows the K-202-DVA to play recorded messages over a paging system. For a description of howthe mode functions, see Operation section B.

Page 7 - D. Local Reset

Once the message repeat count has been met without a response, the K-202-DVA will give a single beep to in-dicate that it has delivered its messages a

Page 8 - Warranty

Printed in the U.S.A.DOD# 305ZF302420 Rev CDue to the dynamic nature of the product design, the information contained in this document is subject to c

Comments to this Manuals

No comments