ES-3
ES-3
Entry System
Door Controller
September 27, 2002
Up to 32 additional points of entry may be added to Viking’s
model AES-2000 Accessible Entry System by adding the
optional AES-NET board. One ES-3, one Wiegand device
and a door strike or magnetic lock of your choice is required
for each additional entry point.
The ES-3 is an entry system door controller designed to oper-
ate a door strike or magnetic lock upon receiving a valid card
read from a Wiegand device. The Wiegand device used may
be the Viking model HID-1 Proximity Card Reader or any
other card reader, RF transmitter or digital keypad that out-
puts the 26 bit Wiegand format. Up to 525 valid Wiegand
codes can be programmed into the AES-2000, and up to
Add Up To 32 Access Entry Points
To Vikings Accessible Entry System
Power: Any 12-24 Volt AC or DC source @ 300mA (not included)
(Designed to share power with the local door strike’s power supply)
Dimensions: 133mm x 89mm x 44mm (5.25” x 3.5” x 1.75”)
Shipping Weight: 1.3 kg (3 lbs)
Environmental: 0° C to 32° C (32° F to 90° F) with 5% to 95%
non-condensing humidity
Relay Contact Ratings: 3A @ 30V DC/250V AC maximum
Connections: 18 screw terminals
Max CAN Length: 0.8 Km (2600 ft) - 24 AWG twisted pair, 1.6 Km,
(5300 ft) - using 2 pairs of 24 AWG twisted pair
Max Wiegand Length: 183 m (500 ft) - 24 AWG
P
P
r
r
a
a
c
c
t
t
i
i
c
c
e
e
T
T
E
E
L
L
E
E
C
C
O
O
M
M
S
S
O
O
L
L
U
U
T
T
I
I
O
O
N
N
S
S
F
F
O
O
R
R
T
T
H
H
E
E
2
2
1
1
S
S
T
T
C
C
E
E
N
N
T
T
U
U
R
R
Y
Y
TECHNICAL
TECHNICAL
1024 access entry events are logged and stored in the AES-2000. Other programmable parameters, like
relay activation and delay times, are also PC programmed via the AES-2000.
Only one pair of wires are needed to wire all 32 Entry System Door Controllers back to the AES-2000.
This two wire CAN communication protocol allows the ES-3 to be installed up to 1 mile away. Power to
the ES-3 can also be daisy chained from unit to unit on a single pair of wires, or simply tap into the local
door strike’s power supply. A door sensor input monitors for a forced door or door ajar condition. A
Request to Exit input operates the doors for people leaving the controlled area. Three separate relay out-
puts allow control of Door Strikes,
Magnetic Locks, Gate Opener, Lights,
Camera and or Alarm.
• Up to 525 tenants
• Up to 32 entry points are possible
• logs up to 1024 entry events
• Two wire CAN communication protocol can
be daisy-chaines together
• Share with door strike’s 12-24 Volt AC or DC
power source
• Inputs may be either normally open (NO) or
normally closed (NC) contacts
• Relay outputs may provide either normally
open (NO) or normally closed (NC) contacts
• High rise apartment buildings
• Condos
• Senior citizen buildings
Assisted care centers
• Retirement homes
• Gated communities
F
F
e
e
a
a
t
t
u
u
r
r
e
e
s
s
P
P
h
h
o
o
n
n
e
e
.
.
.
.
.
.
7
7
1
1
5
5
.
.
3
3
8
8
6
6
.
.
8
8
8
8
6
6
1
1
S
S
p
p
e
e
c
c
i
i
f
f
i
i
c
c
a
a
t
t
i
i
o
o
n
n
s
s
A
A
p
p
p
p
l
l
i
i
c
c
a
a
t
t
i
i
o
o
n
n
s
s
h
h
t
t
t
t
p
p
:
:
/
/
/
/
w
w
w
w
w
w
.
.
v
v
i
i
k
k
i
i
n
n
g
g
e
e
l
l
e
e
c
c
t
t
r
r
o
o
n
n
i
i
c
c
s
s
.
.
c
c
o
o
m
m
i
i
n
n
f
f
o
o
@
@
v
v
i
i
k
k
i
i
n
n
g
g
e
e
l
l
e
e
c
c
t
t
r
r
o
o
n
n
i
i
c
c
s
s
.
.
c
c
o
o
m
m
Page view 0
1 2 3 4 5

Summary of Contents

Page 1 - TECHNICAL

ES-3ES-3Entry SystemDoor ControllerSeptember 27, 2002Up to 32 additional points of entry may be added to Viking’smodel AES-2000 Accessible Entry Syst

Page 2 - Shunt Selections

DDeeffiinniittiioonnssIInnssttaallllaattiioonnCAN Communications: A highly reliable two wire communication protocol originally developed for the autom

Page 3

The ES-3 can be wired with either a normally open or a normally closed Door Sensor switch by setting the shunt locat-ed directly behind the Door Senso

Page 4 - C. Access Cards

PPrrooggrraammmmiinnggEach ES-3 (up to 32 total) must be assigned with its own unique entry point location identifier. With the shunt set toLow Group,

Page 5 - ZF301720 Rev 4

Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, a

Comments to this Manuals