Check damper for unrestricted movement, adjust if
necessary.
2
3
Attach transition to damper. Seal with aluminum tape.
Flip hood over and remove electrical box cover.
1
4
2
1
5
Insert 6” of electrical wiring through the top of vent hood
and secure using wiring restrain. Refer to local codes.
Slide duct over transition and tape around joint.
Planning Information
Proper installation of ducting is extremely
important to ensure maximum performance
from any ventilation product.
All CFMs are based on tests at 0.1 static
pressure: without applying static pressure, CFM
would be greatly overstated.
Straight runs and gradual turns are best; for
example, each 90º elbow is equivalent to 5-10
feet (1.52-3.05 cm) of straight run.
Never use flexible duct; it creates back pressure/air
turbulence and greatly reduces performance.
Proper performance is dependent on proper
ducting; make sure that a qualified and trained
installer is used.
Check with a qualified and trained installer or
local codes for makeup air requirement, if any.
Max. amp rating for hoods includes
recommended ventilator kit rating; all products
must be hard wired direct with 2-wire with ground.
Plan where the duct work will be located. Install
proper-sized duct work, and roof or wall cap for the
type of blower you are using. Recommended hood
locations for the most common installations are
shown. Adjust your measurements for various heights
of ceilings, soffits, cabinets, or ranges/rangetops.
Check Framing
NOTE: Because of the weight of the hood make sure
that the mounting screws are driven into the framing
and not just the drywall. It may be necessary to drill
additional holes in the canopy for proper alignment.
Electrical Supply
Run 120 VAC electrical wiring from service panel
to installation location. See Specifications pages
for the maximum amp requirements.
24
Installation (VWH 10”H. Wall Hoods w/Standard Ventilator)
Roof cap
7
” round duct
Duct cover or soffit
300 or 600 CFM
s
ingle blower
interior-power
typical ductwork
Hood
Roof cap
10” round duct
Duct cover or soffit
1200 CFM
s
ingle blower
interior power
t
ypical ductwork
Hood
Exterior blower
10” round duct
Duct cover or soffit
900, 1200, or
1500 CFM
exterior power
typical ductwork
Hood
Duct
Duct cover or soffit
Wall Installation
exterior power
typical ductwork
NOTE: Wall exhaust must be a minimum of 24” (61.0 cm)
from ground. This may vary depending on local codes
and geographic location.
Hood
Wall cap
W A R N I N G
To reduce the risk of fire, electric shock, or injury
to persons, observe the following:
Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact
the manufacturer.
Before servicing or cleaning unit, switch power off
at service panel and lock service panel to prevent
power from being switched on accidentally. When
the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such
as a tag, to the service panel.