Viking RC-3 Specifications Page 4

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 3
A. Security Access Code
Note: A security access code should be used, when the RC-2A is used on a
line with other equipment that may dial.
1. Setting the Security Access Code
L
L
e
e
g
g
a
a
c
c
y
y
P
P
r
r
o
o
g
g
r
r
a
a
m
m
m
m
i
i
n
n
g
g
M
M
o
o
d
d
e
e
B. DIP Switch Settings
DIP switches 1-7 may be used to change the operation of the RC-2A (see below).
REMOTE TOUCH TONE
RELAY CONTROLLER
VIKING
©
MODEL RC-2A
POWER 12V DC
RELAY
CONTACTS
PROGRAMMING
SWITCHES
ENTRY CODE
N.O.
N.C.
COM
123 12345678
EARTH
GND
PWR IN/OUT
12-24V AC/DC
LINE IN
VIKING
ELECTRONICS
HUDSON, WI 54016
C C
1234567
ON
S1 S2 S3
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
123456 7
ON
ON
OFF
Important: The RC-2A ships by default in the Legacy Programming mode (DIP switch 5 OFF). Optional programming is
also available (see Alternative Programming Mode). The alternative programming mode dramatically changes the pro-
gramming and operation of the RC-2A. Use only the programming features described in the respective sections for the pro-
gramming mode you choose.
The RC-2A contains (3) rotary access/entry code switches (see diagram
right). Using a small flat blade screwdriver, rotate the white arrow on each
switch to the desired access code setting. The code may be any digit 0-9 or
C” (# on a Touch Tone pad). Note: For extreme security applications, a spe-
cial telephone with a 4 x 4 keypad may be used (Fax Back Document 855).
2. Disabling the Security Access Code
If any rotary entry code switch is set to position “D” the security access code
is disabled. In this case, any call to the RC-2A will have immediate access
to activation codes (see page 5, C. Relay Activation Codes). Note: When
the security access code is disabled, the setting of DIP switch 3 has no effect
(unlimited closures allowed).
Switch
1
1
2
2
2
2
3
3
4
4
5
5
6
6
7
7
Description
Latch commands (10 & 19) enabled (factory default)
Latch commands are disabled
Ring delay = 15 (no rotary switches set to C, factory default)
Ring delay = 2 (any rotary switch set to C)
Ring delay = 6 (no rotary switches set to C)
Ring delay = 1 (any rotary switch set to C)
Unlimited number of closures during access time (factory default)
One closure per correct access code during access time
(no rotary switches set to D)
(Not used in the Legacy Programming Mode)
(Not used in the Legacy Programming Mode)
Legacy Programming Mode (factory default)
Alternative Programming Mode
Acknowledgement tones OFF
Acknowledgement tones ON (factory default)
Auto-answer OFF
Auto-answer ON (factory default)
Position
OFF
ON
OFF
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Note: DIP switches are shown
in factory default settings.
If this DIP switch is in the ON position, the relay will not be able to be latched (maintained) and command codes
10 and 19 will be ignored.
Switch 1: Latch Commands
The ring delay is the number of incoming rings before the RC-2A automatically answers the line. The RC-2A
answers on the fifteenth ring by default. This can be changed to the first, second or sixth ring by following the
instructions above for DIP switch 2 and rotary switch positions.
Switch 2: Ring Delay
If this DIP switch is placed in the ON position, only one closure will be allowed during the access.
Switch 3: Closure Limitations
REMOTE TOUCH TONE
RELAY CONTROLLER
VIKING
©
MODEL RC-2A
POWER 12V DC
RELAY
CONTACTS
PROGRAMMING
SWITCHES
ENTRY CODE
N.O.
N.C.
COM
123 12345678
EARTH
GND
PWR IN/OUT
12-24V AC/DC
LINE IN
VIKING
ELECTRONICS
HUDSON, WI 54016
C C
1234567
ON
S1 S2 S3
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Rotary Access/Entry Code Switches
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
4.
Page view 3
1 2 3 4 5 6 7 8

Comments to this Manuals

No comments