Water Filter System Specifi cation and Performance
Data Sheet
This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed
below. The concentration of the indicated substances in water entering the system was reduced to a
concentration of less than or equal to the permissible limit for water leaving the system, as specifi ed in
NSF/ANSI 42/53.* (100% safety factors built-in for unmetered usage for health claims only.)
Contaminant
Reduction
Average
Infl uent
NSF Specifi ed
Challenge
Concentration
Avg %
Reduction
Average
Product Water
Concentration
Max Permissible
Product Water
Concentration
NSF
Reduction
Requirements
NSF Test
Report
Chlorine Taste and
Odor
2.0 mg/L 2.0 mg/L + 10% 97.5% 0.05 mg/L N/A > 50% J-00056501
Nominal Particulate
Class I, >0.5 to <
1.0 µm
13,666,667
pts/mL
At least 10,000
particles/mL
98.9% 143,333
pts/mL
N/A > 85% J-00056506
Asbestos 96 MF/L 10
7
to 10
8
bers/L;
bers greater than
10µm in length
>99% <1 MF/L N/A > 99% J-00056511
Atrazine 0.010 mg/L
0.009 mg/L + 10% 89.3% 0.001 mg/L 0.003 mg/L N/A J-00056512
Cyst* 122,500
cysts/L
Minimum 50,000
cysts/L
99.99% 1 cyst/L N/A > 99.95% J-00056513
Lead @ pH 6.5 0.153 mg/L
0.15 mg/L + 10% 99.3% 0.001 mg/L 0.010 mg/L N/A J-00056515
Lead @ pH 8.5 0.150 mg/L
0.15 mg/L + 10% 99.3% 0.001 mg/L 0.010 mg/L N/A J-00058784
Lindane 0.002 mg/L 0.002 mg/L + 10% 97.8% 0.00004 mg/L 0.0002 mg/L N/A J-00058969
Mercury @ pH 6.5 0.006 mg/L
0.006 mg/L + 10% 95.0% 0.0003 mg/L 0.002 mg/L N/A J-00058785
Mercury @ pH 8.5 0.006 mg/L
0.006 mg/L + 10% 88% 0.0007 mg/L 0.002 mg/L N/A J-00058783
Toxaphene 0.015 mg/L 0.015 mg/L + 10% 93.2% 0.001 mg/L 0.003 mg/L N/A J-00056531
Turbidity 10.8 NTU
11 + 1 NTU 98.7% 0.153 NTU 0.5 NTU N/A J-00058972
*Based on the use of Cryptosporidium parvum oocysts
Operating Specifi cations
Capacity: Certifi ed for up to 750 gallons (2,838 L); up to nine months
Pressure Requirement: 20 - 120 psi (1.4 - 8.2 bar)
Temperature: 33-100º F (0.6 - 37.8º C)
Flow rate: 0.78 gpm (2.9 l/min.)
Check for compliance with the state and local laws and regulations.
Note: While the testing was performed under standard laboratory conditions, actual
performance may vary.
Must be installed and operated in accordance with manufacturer’s recommended procedures
and guidelines. Installation instructions, parts and service availability, and standard warranty
are included with the product when shipped. This drinking water system must be maintained
according to manufacturer’s instruction, including replacement of fi lter cartridges.
Manufactured by: 3M Purifi cation Inc.
400 Research Parkway
Meriden, CT 06770
System tested and certifi ed by NSF International
against Standard 42 for the reduction of chlorine
taste and odor, particulate Class I and Standard 53
for the reduction of Lead, Lindane, Atrazine, Mercury,
Toxaphene, Cyst, Turbidity, and Asbestos.