Viking RC-3 User Manual

Browse online or download User Manual for Battery chargers Viking RC-3. RC-3 Technical Practice

  • Download
  • Add to my manuals
  • Print
  • Page
    / 4
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Remote Control of:
• High security building entry systems
• Door strikes and gates in conjunction with
doorboxes (W-1000, etc.)
• Signs, lights, cameras, sprinklers, motors
• Other contact controlled equipment
• Can also be used as an emergency dialer for
alarm systems, etc.
RC-3
RC-3
3 Relay Remote Touch
Tone Controller
February 22, 2010
The RC-3 enables a standard Touch Tone
phone to control up to 3 maintained ON, main-
tained OFF, or momentary relay contacts from
a remote location. The RC-3 is fully user pro-
grammable and uses non-volatile E
2
memory.
Up to three RC-3’s can be daisy chained on
the same line to control up to nine relays.
The RC-3 features switchable 12V talk battery
allowing easy installation on the trunk port. In
addition, the unit can be connected directly to
a C.O. line or analog PABX/KSU station.
Control 1 to 9 Relays Remotely
P
P
h
h
o
o
n
n
e
e
.
.
.
.
.
.
7
7
1
1
5
5
.
.
3
3
8
8
6
6
.
.
8
8
8
8
6
6
1
1
h
h
t
t
t
t
p
p
:
:
/
/
/
/
w
w
w
w
w
w
.
.
v
v
i
i
k
k
i
i
n
n
g
g
e
e
l
l
e
e
c
c
t
t
r
r
o
o
n
n
i
i
c
c
s
s
.
.
c
c
o
o
m
m
• User Touch Tone programmable
• Non-volatile E
2
memory
• 12 digit alarm activated pulse dialer
• 6 digit security code (to access programming)
• 6 digit access code (disable or enable for
additional control security)
• Switchable 12V talk battery
• Relay interrogation tones
• Programmable relay time delays
• Cascade up to three RC-3’s to control up to
nine relays
• Programmable ring delay before answering
• Status LED’s for relays 1, 2, 3 and the
answer relay
• One power adaptor can power up to three
units
Power: 120V AC/12V DC 500mA UL listed adapter provided
Shipping Weight: 0.54 kg (1.2 lbs)
Dimensions: 133mm x 89mm x 44mm (5.25” x 3.5” x 1.75”)
Environmental: 0°C to 32°C (32°F to 90°F) with 5% to 95%
non-condensing humidity
Pulse Dialing Speed: 10 pps
Talk Battery Output: 12V DC minimum (15V nominal)
Relay contact ratings: .5A @ 125V AC/1A @ 30V DC
On hook time between alarm dialing: 2.5 seconds
Connections: (2) RJ11 jacks, 10 position screw terminal strip
P
P
r
r
a
a
c
c
t
t
i
i
c
c
e
e
T
T
E
E
L
L
E
E
C
C
O
O
M
M
S
S
O
O
L
L
U
U
T
T
I
I
O
O
N
N
S
S
F
F
O
O
R
R
T
T
H
H
E
E
2
2
1
1
S
S
T
T
C
C
E
E
N
N
T
T
U
U
R
R
Y
Y
TECHNICAL
TECHNICAL
F
F
e
e
a
a
t
t
u
u
r
r
e
e
s
s
S
S
p
p
e
e
c
c
i
i
f
f
i
i
c
c
a
a
t
t
i
i
o
o
n
n
s
s
The RC-3 also features a built in pulse dialer activated by a contact closure from an
alarm system, temperature sensor, etc. The RC-3 will dial the number up to three times
sending alert tones indicating an emergency.
A
A
p
p
p
p
l
l
i
i
c
c
a
a
t
t
i
i
o
o
n
n
s
s
i
i
n
n
f
f
o
o
@
@
v
v
i
i
k
k
i
i
n
n
g
g
e
e
l
l
e
e
c
c
t
t
r
r
o
o
n
n
i
i
c
c
s
s
.
.
c
c
o
o
m
m
Page view 0
1 2 3 4

Summary of Contents

Page 1 - TECHNICAL

Remote Control of:• High security building entry systems• Door strikes and gates in conjunction with doorboxes (W-1000, etc.)• Signs, lights, camer

Page 2 - A. Single RC-3 Installation

IInnssttaallllaattiioonnB. Expanding To Control From 4 to 9 RelaysTwo or three RC-3’s can be daisy chained to the same line to control 1 to 9 relays.

Page 3

C. Quick Programming FeaturesB. Security CodeThe Security Code number allows the user/installer to change the unit’s programming. To enter your own Se

Page 4 - TOUCH TONE CONTROLLER

Description1. Latching relay 2 from a remote location with the access codeprogrammed to 123456 and enabled2. Starting the timed activation of Relay 3

Comments to this Manuals