Viking E-40 Specifications Page 8

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 7
Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries
assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate such changes.
DOD# 191
ZF302450 Rev F
Printed in the U.S.A.
P
P
r
r
o
o
d
d
u
u
c
c
t
t
S
S
u
u
p
p
p
p
o
o
r
r
t
t
L
L
i
i
n
n
e
e
.
.
.
.
.
.
7
7
1
1
5
5
.
.
3
3
8
8
6
6
.
.
8
8
6
6
6
6
6
6
F
F
a
a
x
x
B
B
a
a
c
c
k
k
L
L
i
i
n
n
e
e
.
.
.
.
.
.
7
7
1
1
5
5
.
.
3
3
8
8
6
6
.
.
4
4
3
3
4
4
5
5
8
LED3
LED1 LED2
LED4
LED5
LED6
LED7
C
CCCC
C C
J11-
1
2
3
J10-
12
3
J9-
1
2
3
J8-
1
2
3
J7-
1
2
3
123
on
4 5
VIKING
©
MODEL C-2000B
VIKING
ELECTRONICS
HUDSON, WI 54016
ADVANCED DOOR/GATE AND
ENTRY PHONE CONTROLLER
1 2 3 4 5 6 7
89
10 11 12 13 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
PWR 13.8 VAC
EARTH GND
ENTRY PHONE 1
DOOR STRIKE 1
ENTRY PHONE 2
DOOR STRIKE 2
ENTRY PHONE 3
DOOR STRIKE 3
ENTRY PHONE 4
DOOR STRIKE 4
DOORBELL SWITCH /
AUX. INPUT
AUX. CONTACT
OUTPUT
PHONE LINE
INPUT
LINE OUT
TO PHONES
ANALOG STATION
INPUT
Entry Phone 1
E-50-SS shown
(Example: Front Door)
C.O. / Phone
Line Input
To Standard
Analog Touch
Tone House
Phone(s)
or
Entry Phone 4,
K-1700-3 shown,
not included
(Example: Gate)
Entry Phone 2, E-50-SS shown,
not included (Example: Back Door)
To Entry Phone 4
(Power typically not
required for gate controllers)
Doorstrike/
Magnetic Lock
5A@30VDC/
250VAC
maximum
A contact closure output is available for each
entry phone. An auxiliary output is also available.
* Earth
Ground
(optional)
Optional Doorbell Switch
(not included, see Programming
section L on page 5)
Optional
Postal Lock
(not included)
See DIP Switch Programming
Programming section C (page 4)
13.8V AC
Adapter
(included)
120V AC
Entry Phone 3, E-30 shown,
not included (Example: Garage)
To Gate
Controller
Tip (Audio)
Ring
Tip (Audio)
Ring
Video Out
Example:
2-4 Channel Video
RF Modulator
Example:
Amplified
RF Splitter
Video Out
Multi Room
Video Out
02
Antenna,
CATV, etc.
1 2 3 4
Model C-2000B (not included)
For more information on the
C-2000B, see DOD# 156.
B. One to Four Entry Phones Sharing a Single Phone Line with Optional Keyless Entry,
Doorstrike/Gate Control, and Entry Phone Caller ID
A
A
p
p
p
p
l
l
i
i
c
c
a
a
t
t
i
i
o
o
n
n
s
s
E-50-SS
shown
E-50-SS
shown
13.8V AC
Adapter
included
120V AC
Door 1
Entry
Phone
Door 2
Entry
Phone
Standard
Analog Phone(s)
-OR-
Analog Trunk / Line
Input of a Phone System
C.O. / Phone
Line Input
VIKING©
VIKING
ELECTRONICS
HUDSON,
WI
54016
ADVANCED 2 DOOR ENTRY PHONE
CONTROLLER WITH CALL FORWARDING
POWER 13.8V AC
MODEL C-500
PHONE LINE
INPUT
LINE OUT
TO PHONES
1234
ENTRY
PHONE 1
56 789
DOOR
STRIKE 1
N.C.
N.O.
COM
ENTRY
PHONE 2
13 14
SLP
CONTROL
18
+
19
TRIGGER
INPUT 1
10 11 12
TRIGGER
INPUT 2
15 16 17
DOOR
STRIKE 2
N.C.
N.O.
COM
(Power typically not
required for gate controllers)
Doorstrike/
Magnetic Lock 1
Doorstrike/
Magnetic Lock 2
5A@30VDC/
250VAC
maximum
Model C-500 (not included)
For more information on the
C-500, see DOD# 177.
A. 1 or 2 (Expandable to 8) E-50’s Sharing a Single Line with Optional Call Forwarding and
Doorstrike/Gate Control
Page view 7
1 2 3 4 5 6 7 8

Comments to this Manuals