Viking C-1000B Specifications Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
(5)
G. Adding Paging to Homes and Small Businesses with Single Line Phones
The C-1000B can be used to control a paging amplifier from a single phone line. The amplifier used must provide talk
battery, such as the Viking model PA-2A (Fax Back Document 485) or CPA-7B (Fax Back Document 455). If need
be, a doorbox or a second paging amplifier may also be added to the C-1000B Doorbox 2 terminals (see Installation
section A). Note: The C-1000B must be programmed to be in the Paging Mode, 4 (see Programming section B
and Operation section B).
DOOR ENTRY / CCTV VIDEO
/ PAGING CONTROLLER
VIKING
©
MODEL C-1000B
PWR 13.8 VAC
DOOR
STRIKE 1
DOOR
STRIKE 2
DOORBO
X 2
DOORBO
X
PWR OUTPUT
DOORBOX 1
123456789
10 11 12 13
14 15 16 17 18 19
EARTH
GND
PHONE LINE
INPUT
LINE OUT
TO PHONES
KEYLESS CONTACT
CLOSURE INPUT
VIKING
ELECTRONICS
HUDSON, WI 54016
EARTH
GND
C.O. LINE
INPUT
OUT TO
PHONES
KEYLESS
C.C. INPUT
DOOR
BOX 1
DOORBOX
13VAC PWR
DOOR
BOX 2
N.O. COM N.C.
DOOR STRIKE 1
SIG GND
VIDEO 1 IN
SIG GND
VIDEO 2 IN
SIG GND
VIDEO OUT
N.O. COM N.C.
DOOR STRIKE 2
TALK BATTERY
OFF ON
C
LED1
C
LED2
C
LED3
ON
1 2 3
COM N.O. N.C. - - - - AUX.
CONTACT
OUTPUT
PAGING - LOUD RINGING
AMPLIFIER SYSTEM
VIKING
ELECTRONICS
HUDSON, WI 54016
VIKING
©
MODEL PA-2A
P
O
W
ER
13.8
V
A
C
12345678 910
N
IG
HT
TR
AN
SF
ER
SW
ITC
H
IN
P
U
T
P
A
GING
H
O
RN
600 OHM
AUD
IO
O
UTP
UT
TR
U
N
K
/ P
A
G
ING
P
O
R
T
DR
Y CO
N
T
AC
T
C
LO
SU
R
E IN
PU
T
RINGING
VOLUME
MAX
MIN
1 - 3 4 - 6
RINGING LINES
1 2 3 4
TALK BATTERY
ALERT TONE
WARBLE / CHIME
PAGING
VOLUME
MAX
MIN
POWER
JP1
C.O. Line
or Analog
PABX/KSU
station
13.8V AC
Adapter
included
120V AC
or
Standard
Analog
Phones
Unused
Trunk
Input of
PABX/KSU
25AE Paging
Horn
Talk Battery Switch
OFF ON
Earth Ground
(see page 2)
H. Using the C-1000B on an Analog Station Port (Analog PABX/KSU Station Mode)
This application is ideal for connecting the C-1000B to an unused analog station of your phone system. See
Programming section F and Operation section A. Important: In this application, only a single door phone is used and
5 must be selected when in programming.
DOOR ENTRY / CCTV VIDEO
/ PAGING CONTROLLER
VIKING
©
MODEL C-1000B
PWR 13.8 VAC
DOOR
STRIKE 1
DOOR
STRIKE 2
DOORBOX 2
DOORBOX
PWR OUTPUT
DOORBOX 1
123456789
10 11 12 13
14 15 16 17 18 19
EARTH
GND
PHONE LINE
INPUT
LINE OUT
TO PHONES
KEYLESS CONTACT
CLOSURE INPUT
VIKING
ELECTRONICS
HUDSON, WI 54016
EARTH
GND
C.O. LINE
INPUT
OUT TO
PHONES
KEYLESS
C.C. INPUT
DOOR
BOX 1
DOORBOX
13VAC PWR
DOOR
BOX 2
N.O. COM N.C.
DOOR STRIKE 1
SIG GND
VIDEO 1 IN
SIG GND
VIDEO 2 IN
SIG GND
VIDEO OUT
N.O. COM N.C.
DOOR STRIKE 2
TALK BATTERY
OFF ON
C
LED1
C
LED2
C
LED3
ON
1 2 3
COM N.O. N.C. - - - - AUX.
CONTACT
OUTPUT
13.8V AC
Adapter
included
120V AC
or
Standard
Analog Phone
K-1900-5
Dialer
* K-1700-3
Phone
E-1600A
Phone
Talk Battery Switch
OFF ON
Analog
PABX/KSU
station
E-30
Speaker Phone
Earth Ground
(see page 2)
E-10 or E-20A
Speaker Phones
E-10 or E-20A
Speaker Phones
Doorstrike/Magnetic Lock 1
5A@30V DC/250V AC maximum
120V AC
Model
E-10/E-20A
E-30
E-1600A
K-1700-3
K-1900-5
Fax #
210
212
215
157
317
Description
Handsfree Speaker Phone
Vandal Resistant Handsfree Speaker Phone
Emergency/Elevator Phone
Handsfree Speaker Phone with Keypad
Touch Tone Dialer
?
Need More Information on the PA-2A?
Call (715) 386-4345 and select 485.
Need more information on the products shown to the right?
Call 715-386-4345 and enter the number below:
Note: The E-10 and E-20A
Speaker Phones may be
used with
or without a
dialer, depending on the
application.
* Note: The K-1700-3’s keypad can be used for extension
dialing, etc., but can NOT be used for keyless entry (see
Installation and Applications section D).
Page view 4
1 2 3 4 5 6 7 8

Comments to this Manuals